Solas ISM regulation
In 1998, the Internatianal Safety Management (ISM code) was adopted by IMO and became mandatory on certain ocean going vessels.
In 2002 the Safety Of Life At Sea (SOLAS), chapter IX and the ISM code applies to all ships. The Sika calibration equipment (temperature calibrators and pressure calibrators) will enable ship owners and marine engineers to comply with the SOLAS regulation for maintenance standards. We advise a recalibration of the calibrator with a cycle between 1 and 2 yeras depending on strain.
The calibrator comprises:
On board:
Sika recalibration set
Sika in house:
Calibrator adjustment (only made by Sika DKD laboratory) with output certificate.
Economic and safe!
Exact temperature measurement and monitoring are "musts" in applications crucial to operational safety of machinery and industrial installations.
Regular inspection of the temperature sensors used in these applications is essencial for economic and technical safety reasons and is already prescribed as obligatory in many sectors.
The temperature calibrators and calibrator bath are already a part of the standard equipment of the technician in the above listed sectors.
These compact devices are easy to transport and easy to operate and have all performance features required for "in-situ inspection".
For inspection of Sika thermometers
Inspection is performed by comparison of the temperature vmeasured by the test piece and the block temperature indicated by the calibrator/calibrator bath.
For inspection of temperature switches/thermostats
The test piece is inersted into the block and connected to the external transducer.
The switch setting respective to the switch point is signaleed by reached temperature.
For inspection of resistance thermometers and thermocouples
The inspection is performed by comparison of the temperature indicated on the external measuring instrument with the refernce temperature of the calibrator or calibration bath.
Description
The calibrators of series TP 17 000 M contain an electrically controlled metal block with a bore for the insertion of the test piece.Adapter sleeves are used for test pieces with smaller diameter.
The block is mounted in a heat insulated housing. The complete electronic is located in the front of the calibrator. The required temperature is easily set on the digital controller.
The current temperature will automatically be adjusted to the set value. The current temperature and set temperature are constantly shown on the 2-line, 4-digit, 7-segment LEd display.